Special Services such as liquid level test by echometering and SRP monitoring
Siam Company provides many kinds of special services such as liquid level test by echometering, acoustic well sounding for pumping wells (ESP, SRP, PCP) and SRP monitoring
Echometering
- Flowing and Static liquid level measurements
- Flowing & Static Bottom-Hole pressure (FBHP & SBHP) calculations
Sucker rod pump (SRP) performance monitoring
- Dynamometer data test (loads, pump card recording, SPM, stroke length, valve testing)
Acoustic well sounding testing for pumping wells (acoustic pressure transient testing)
- Multiple – Rate testing
- Transient Pressure fluid build-up testing (fluid build-up)
There are several difficulties to test pumping wells with sucker rod pumps, electrical submersible pumps (ESP) or progressive cavity pumps (PCP). Testing pumping wells by removing the pump from the hole is quite expensive and not practical. SIAM Company provides a cost-effective alternative to test pumping wells without packer based on acoustic well-sounding techniques. The bottomhole pressure is calculated from indirect measurements (casing head pressure and the height of rising liquid column in the annulus.